Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2004.040311v1, 2004; 10.1373/clinchem.2004.040311
This Article
Right arrow Full Text (PDF)
Right arrow Data Supplements
Right arrow All Versions of this Article:
clinchem.2004.040311v1
51/2/305    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Girald-Rosa, W.
Right arrow Articles by Sligh, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Girald-Rosa, W.
Right arrow Articles by Sligh, J. E.

Received on July 16, 2004
Accepted on November 18, 2004

Molecular Diagnostics and Genetics

High-Throughput Mitochondrial Genome Screening Method for Nonmelanoma Skin Cancer Using Multiplexed Temperature Gradient Capillary Electrophoresis

Willie Girald-Rosa 1, Ruth A. Vleugels 1, Amy C. Musiek 1, James E. Sligh 1*

1 VA Tennessee Valley Healthcare System, Department of Medicine, Division of Dermatology, and Department of Cell and Developmental Biology, Vanderbilt University Medical Center, Nashville, TN

* To whom correspondence should be addressed. E-mail: james.sligh{at}vanderbilt.edu.

Background: We explored the utility of multiplexed temperature gradient capillary electrophoresis (TGCE) as a screening tool for identifying genetic changes in the human mitochondrial genome. We examined changes in mitochondrial DNA (mtDNA) in nonmelanoma skin cancers (NMSCs) using TGCE to resolve genetic differences contained within the tumors compared with the control DNA.

Methods: The entire mtDNA from NMSC tissue samples was amplified in 17 overlapping amplicons averaging 1.1 kb in size. Fourteen of these amplicons were digested with restriction endonucleases into as many as five smaller analyzable fragments. Digested tumor mtDNA amplicons were annealed with digested amplicons from the control DNA to form heteroduplexes in regions of DNA mismatch. TGCE was performed in a 96-well parallel format to detect mtDNA changes in a high-throughput fashion.

Results: TGCE resolved heteroduplexes from homoduplexes in singlet reactions and in multiplexed assays. Using a single programmed temperature gradient, we detected 18 of 20 mtDNA changes contained within the specimens. This system was also able to detect a single nucleotide change in a fragment as large as 2 kb.

Conclusion: Multiplexed TGCE is a sensitive and high-throughput screening tool for identifying mtDNA variations.




The following articles in journals at HighWire Press have cited this article:


Home page
Physiol. GenomicsHome page
J. Grosse, P. Tarnow, H. Rompler, B. Schneider, R. Sedlmeier, U. Huffstadt, D. Korthaus, M. Nehls, S. Wattler, T. Schoneberg, et al.
N-ethyl-N-nitrosourea-based generation of mouse models for mutant G protein-coupled receptors
Physiol Genomics, September 14, 2006; 26(3): 209 - 217.
[Abstract] [Full Text] [PDF]


Home page
GeneticsHome page
Y. Jiao, J. Yan, Y. Zhao, L. R. Donahue, W. G. Beamer, X. Li, B. A. Roe, M. S. LeDoux, and W. Gu
Carbonic Anhydrase-Related Protein VIII Deficiency Is Associated With a Distinctive Lifelong Gait Disorder in Waddles Mice
Genetics, November 1, 2005; 171(3): 1239 - 1246.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2004 by the American Association for Clinical Chemistry.