Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2005.057323v1, 2006; 10.1373/clinchem.2005.057323
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2005.057323v1
52/3/389    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sviridov, D.
Right arrow Articles by Hortin, G. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sviridov, D.
Right arrow Articles by Hortin, G. L.

Received on July 7, 2005
Accepted on December 7, 2005

Proteomics and Protein Markers

Coelution of Other Proteins with Albumin during Size-Exclusion HPLC: Implications for Analysis of Urinary Albumin

Denis Sviridov 1, Bonnie Meilinger 1, Steven K. Drake 2, Gerard T. Hoehn 2, Glen L. Hortin 1*

1 Department of Laboratory Medicine, Warren Magnuson Clinical Center, National Institutes of Health, Bethesda, MD
2 Department of Critical Care Medicine, Warren Magnuson Clinical Center, National Institutes of Health, Bethesda, MD

* To whom correspondence should be addressed. E-mail: ghortin{at}mail.cc.nih.gov.

Background: Size-exclusion HPLC has been used as an alternative to immunoassays for quantifying urinary albumin (microalbumin). Systematically higher values for the HPLC method have been proposed to result from nonimmunoreactive albumin.

Methods: We evaluated separation of purified proteins and urinary components by size-exclusion HPLC using a Zorbax Bio Series GF-250 column eluted with phosphate-buffered saline. Urinary components eluting in the "albumin" peak were analyzed by mass spectrometry and reversed-phase HPLC.

Results: Several proteins, such as transferrin, {alpha}1-proteinase inhibitor, {alpha}1-acid glycoprotein, and {alpha}2-HS glycoprotein, analyzed as purified components, were not resolved from albumin by size-exclusion HPLC. Peaks for other proteins, such as IgG and urinary components identified as dimers of {alpha}1-microglobulin and immunoglobulin light chains, overlapped with the albumin peak. Profiles of urine specimens showed variable amounts of components overlapping with albumin. Furthermore, the albumin peak obtained by size-exclusion HPLC was found by mass spectrometry and reversed-phase HPLC to contain multiple components in addition to albumin.

Conclusions: Size-exclusion HPLC does not resolve albumin from several other proteins in urine. The albumin peak resolved by this technique, although predominantly composed of albumin, contains several coeluting globulins that would contribute to overestimation of albumin concentration by size-exclusion HPLC.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2006 by the American Association for Clinical Chemistry.