Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2005.066019v1, 2006; 10.1373/clinchem.2005.066019
This Article
Right arrow Full Text (PDF)
Right arrow 066019.Supplemental Data
Right arrow All Versions of this Article:
clinchem.2005.066019v1
52/8/1584    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramsden, S. C.
Right arrow Articles by Verderio, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramsden, S. C.
Right arrow Articles by Verderio, P.

Received on January 3, 2006
Accepted on May 16, 2006

Laboratory Management

EQUAL-quant: An International External Quality Assessment Scheme for Real-Time PCR

Simon C. Ramsden 1*, Sarah Daly 2, Wolf-Jochen Geilenkeuser 3, Graeme Duncan 4, Fabienne Hermitte 4, Ettore Marubini 5, Michael Neumaier 6, Claudio Orlando 7, Vladimir Palicka 8, Angelo Paradiso 9, Mario Pazzagli 7, Sara Pizzamiglio 1, Paolo Verderio 1

1 National Genetics Reference Laboratory (Manchester), St. Mary's Hospital, Manchester, UK
2 Molecular Diagnostic Centre, Manchester Royal Infirmary, Manchester, UK
3 DGKL-Reference Institute for Bioanalytics, Bonn, Germany
4 Ipsogen, Luminy Biotech Enterprises, Marseilles, France
5 Institute of Medical Statistics and Biometry, University of Milan, Milan, Italy
6 Institute for Clinical Chemistry, University Hospital Mannheim of the University of Heidelberg, Heidelberg, Germany
7 Clinical Biochemistry Unit, Department of Clinical Physiopathology, University of Florence, Florence, Italy
8 Institute for Clinical Biochemistry and Diagnostics, School of Medicine, University Hospital Sokolska, Hradec Kralove, Czech Republic
9 National Cancer Institute, Bari, Italy

* To whom correspondence should be addressed. E-mail: simon.ramsden{at}cmmc.nhs.uk.

Background: Quantitative gene expression analysis by real-time PCR is important in several diagnostic areas, such as the detection of minimum residual disease in leukemia and the prognostic assessment of cancer patients. To address quality assurance in this technically challenging area, the European Union (EU) has funded the EQUAL project to develop methodologic external quality assessment (EQA) relevant to diagnostic and research laboratories among the EU member states. We report here the results of the EQUAL-quant program, which assesses standards in the use of TaqManTM probes, one of the most widely used assays in the implementation of real-time PCR.

Methods: The EQUAL-quant reagent set was developed to assess the technical execution of a standard TaqMan assay, including RNA extraction, reverse transcription, and real-time PCR quantification of target DNA copy number.

Results: The multidisciplinary EQA scheme included 137 participating laboratories from 29 countries. We demonstrated significant differences in performance among laboratories, with 20% of laboratories reporting at least one result lacking in precision and/or accuracy according to the statistical procedures described. No differences in performance were observed for the >10 different testing platforms used by the study participants.

Conclusions: This EQA scheme demonstrated both the requirement and demand for external assessment of technical standards in real-time PCR. The reagent design and the statistical tools developed within this project will provide a benchmark for defining acceptable working standards in this emerging technology.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. A. Bustin, V. Benes, J. A. Garson, J. Hellemans, J. Huggett, M. Kubista, R. Mueller, T. Nolan, M. W. Pfaffl, G. L. Shipley, et al.
The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments
Clin. Chem., April 1, 2009; 55(4): 611 - 622.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Orlando, P. Verderio, R. Maatman, J. Danneberg, S. Ramsden, M. Neumaier, D. Taruscio, V. Falbo, R. Jansen, C. Casini-Raggi, et al.
EQUAL-qual: A European Program for External Quality Assessment of Genomic DNA Extraction and PCR Amplification
Clin. Chem., July 1, 2007; 53(7): 1349 - 1357.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Dorn-Beineke, P. Ahmad-Nejad, U. Pfeiffer, S. Ramsden, M. Pazzagli, and M. Neumaier
Improvement of Technical and Analytical Performance in DNA Sequencing by External Quality Assessment-Based Molecular Training
Clin. Chem., November 1, 2006; 52(11): 2072 - 2078.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2006 by the American Association for Clinical Chemistry.