Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2006.075184v1, 2006; 10.1373/clinchem.2006.075184
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2006.075184v1
53/1/98    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nellåker, C.
Right arrow Articles by Karlsson, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nellåker, C.
Right arrow Articles by Karlsson, H.

Received on June 19, 2006
Accepted on October 19, 2006

Automation and Analytical Techniques

Molecular Beacon-Based Temperature Control and Automated Analyses for Improved Resolution of Melting Temperature Analysis Using SYBR I Green Chemistry

Christoffer Nellåker 1*, Ulf Wållgren 2, Håkan Karlsson 1

1 Department of Neuroscience, Karolinska Institutet, Stockholm, Sweden
2 FLIR Systems AB, Danderyd, Sweden

* To whom correspondence should be addressed. E-mail: christoffer.nellaker{at}ki.se.

Introduction:Melting temperature analysis of products amplified with SYBR I Green chemistry is a cheap and effective method for identification of sequence differences. When used in conventional quantitative real-time PCR instruments (qPCR), this method is limited by temperature variations over the heating block and low numbers of fluorescence measurements during the dissociation step, which hamper the ability of most instruments to report accurate and precise melting temperatures.

Methods: We designed a molecular beacon-based temperature indicator probe (Tm-probe) to control for variations in temperatures over the heating block of the instrument. In addition, we wrote an automated curve-fit analysis algorithm of dissociation data to use multiple data points with a gaussian curve fit to extrapolate precise melting temperatures.

Results: Use of the Tm-probe in conjuction with the analysis algorithm and multiple dissociations improved SDs of melting temperatures over a 96-well plate from 0.19 to 0.06 °C

Conclusions: Melting temperature analyses with SYBR I Green chemistry on conventional qPCR instruments can be improved by the use of a Tm-probe in conjunction with curve-fit analysis of data. Resolution improvement up to 3-fold is possible and allows additional melting temperatures to be identified.




The following articles in journals at HighWire Press have cited this article:


Home page
Nucleic Acids ResHome page
C. N. Gundry, S. F. Dobrowolski, Y. R. Martin, T. C. Robbins, L. M. Nay, N. Boyd, T. Coyne, M. D. Wall, C. T. Wittwer, and D. H.-F. Teng
Base-pair neutral homozygotes can be discriminated by calibrated high-resolution melting of small amplicons
Nucleic Acids Res., June 1, 2008; 36(10): 3401 - 3408.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. G. Herrmann, J. D. Durtschi, C. T. Wittwer, and K. V. Voelkerding
Expanded Instrument Comparison of Amplicon DNA Melting Analysis for Mutation Scanning and Genotyping
Clin. Chem., August 1, 2007; 53(8): 1544 - 1548.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2006 by the American Association for Clinical Chemistry.