Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2006.077560v1, 2007; 10.1373/clinchem.2006.077560
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2006.077560v1
53/6/1104    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seiden-Long, I.
Right arrow Articles by Vieth, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seiden-Long, I.
Right arrow Articles by Vieth, R.

Received on August 1, 2006
Accepted on March 20, 2007

Endocrinology and Metabolism

Evaluation of a 1,25-Dihydroxyvitamin D Enzyme Immunoassay

Isolde Seiden-Long 1 Reinhold Vieth 2*

1 Department of Laboratory Medicine and Pathobiology, Mount Sinai Hospital, Toronto, Canada
2 Department of Laboratory Medicine and Pathobiology, Mount Sinai Hospital, Toronto, Canada, and Department of Nutritional Sciences, University of Toronto, Toronto, Canada

* To whom correspondence should be addressed. E-mail: rvieth{at}mtsinai.on.ca.

Background: Radioactive reagents are used in most assays for measurement of 1,25-dihydroxyvitamin D [1,25(OH)2D]. We evaluated a 1,25(OH)2D enzyme immunoassay (EIA) from IDS Ltd. that uses solid-phase immunoextraction and colorimetric detection and compared results to those of the thymus radioreceptor assay (RRA) for 1,25(OH)2D.

Methods: We collected serum samples (n = 145) representing an even distribution (0-200 pmol/L) of 1,25(OH)2D concentrations and Vitamin D External Quality Assessment Scheme (DEQAS) proficiency survey samples from 2004 surveys (n = 15) and stored them at -20 °C. We analyzed all samples with both EIA and RRA methods. We calculated imprecision using 5 QC samples in quadruplicate in each run (n = 6), including both pooled patient material used for QC with the RRA and QC material included in the EIA reagent set. We evaluated calibration stability by analyzing calibrators from different lots on the same plate and determining if calculated sample values drifted significantly.

Results: Deming linear regression between IDS EIA and RRA methods yielded slope 1.25 (95% CI 1.13-1.37), y-intercept -3 (95% CI -18 to 12), R2 = 0.74. DEQAS proficiency survey samples for 2004 were all within 30% of the all-methods-trimmed mean. Imprecision CVs were 12%-16% within-run and 15%-20% between-run.

Conclusions: We find no evidence of inferiority to the classic calf-thymus receptor assay for 1,25(OH)2D and no disadvantage in the results generated by the IDS EIA using samples from the major proficiency survey for 1,25(OH)2D. According to the product insert, however, the IDS EIA underestimates 1,25(OH)2D2 compared with the D3 form.




The following articles in journals at HighWire Press have cited this article:


Home page
Anticancer ResHome page
T. NITTKE, E. KALLAY, T. MANHARDT, and H. S. CROSS
Parallel Elevation of Colonic 1,25-Dihydroxyvitamin D3 Levels and Apoptosis in Female Mice on a Calcium-deficient Diet
Anticancer Res, September 1, 2009; 29(9): 3727 - 3732.
[Abstract] [Full Text] [PDF]