Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2006.082271v1, 2007; 10.1373/clinchem.2006.082271
This Article
Right arrow Full Text (PDF)
Right arrow 082271.Supplemental Data
Right arrow All Versions of this Article:
clinchem.2006.082271v1
53/6/1061    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Li, Y.-Y.
Right arrow Articles by Xu, S.-Q.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Li, Y.-Y.
Right arrow Articles by Xu, S.-Q.

Received on October 31, 2006
Accepted on March 14, 2007

Proteomics and Protein Markers

Ultrasensitive Densitometry Detection of Cytokines with Nanoparticle-Modified Aptamers

Yuan-Yuan Li 1, Chi Zhang 1, Bo-Sheng Li 1, Li-Fan Zhao 1, Xiao-bo Li 1, Wen-Jie Yang 1, Shun-Qing Xu 1*

1 MOE Key Laboratory of Environment and Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China

* To whom correspondence should be addressed. E-mail: shunqing{at}mails.tjmu.edu.cn.

Background: Aptamers mimic properties of antibodies and sometimes turn out to be even better than antibodies as reagents for assays. We describe the establishment of an ultrasensitive densitometry method for cytokine detection by nanoparticle (NP)-modified aptamers.

Methods: The assay simultaneously uses a gold NP-modified aptamer and a biotin-modified aptamer to bind to the target protein, forming a sandwich complex. The absorbance signal generated by the aptamer-protein complex is amplified and detected with a microplate reader.

Results: The assay for platelet-derived growth factor B-chain homodimer (PDGF-BB) was linear from 1 fmol/L to 100 pmol/L (R2 = 0.9869). The analytical detection limit was 83 amol/L. The intraassay and interassay imprecision (coefficient of variations) was ≤7.5%. Serum concentrations of PDGF-BB determined with the gold NP-modified aptamer assay and with ELISA were not significantly different.

Conclusions: The gold NP-modified aptamer assay provides a fast, convenient method for cytokine detection and improves the detection range and the detection limit compared with ELISA.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2007 by the American Association for Clinical Chemistry.