Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2006.083915v1, 2007; 10.1373/clinchem.2006.083915
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2006.083915v1
53/5/911    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fritz, K. S.
Right arrow Articles by Nelson, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fritz, K. S.
Right arrow Articles by Nelson, J. C.

Received on November 29, 2006
Accepted on February 5, 2007

Endocrinology and Metabolism

A Direct Free Thyroxine (T4) Immunoassay with the Characteristics of a Total T4 Immunoassay

Kristofer S. Fritz 1, R. Bruce Wilcox 1, Jerald C. Nelson 2*

1 Department of Biochemistry, Loma Linda University School of Medicine, Loma Linda, CA
2 Department of Internal Medicine and Pathology, Loma Linda University School of Medicine, Loma Linda, CA

* To whom correspondence should be addressed. E-mail: jcnelson{at}llu.edu.

Background: Direct free thyroxine (T4) measurements have been linked to both T4-binding serum protein concentrations and protein-bound T4 concentrations. Whether this is evidence of a relationship to total T4 concentrations has not been reported.

Methods: We compared an analog-based direct free T4 immunoassay and a total T4 immunoassay. Each assay was applied to the fractions of serum T4 obtained by ultrafiltration and equilibrium dialysis. Both were applied to serum-based solutions in which free T4, T4-binding proteins, protein-bound T4, and total T4 were systematically varied, held constant, or excluded.

Results: Neither the free T4 assay nor the total T4 assay detected dialyzable or ultrafilterable serum T4. Both assays detected and reported the T4 retained with serum proteins. Both free and total T4 results were related to the same total T4 concentrations in the presence and absence of T4-binding proteins. Both results were similarly related to total T4 concentrations when free T4 was held constant while total T4 was varied. Both were similarly related to a total T4 concentration that was held constant while free T4 progressively replaced protein-bound T4. These free T4 results, like total T4 results, were unresponsive to a 500-fold variation in dialyzable T4 concentrations.

Conclusion: New experiments extend the characterization of a longstanding and incompletely characterized analog-based free T4 immunoassay. These free T4 measurements relate to total T4 concentrations in the same way that total T4 measurements do.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
K. S. Fritz, A. J.S. McKean, J. C. Nelson, and R. B. Wilcox
Analog-Based Free Testosterone Test Results Linked to Total Testosterone Concentrations, Not Free Testosterone Concentrations
Clin. Chem., March 1, 2008; 54(3): 512 - 516.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. S. Fritz, R. M. Weiss, J. C. Nelson, and R. B. Wilcox
Unequal Concentrations of Free T3 and Free T4 after Ultrafiltration
Clin. Chem., July 1, 2007; 53(7): 1384 - 1385.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2007 by the American Association for Clinical Chemistry.