Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2007.088393v1, 2007; 10.1373/clinchem.2007.088393
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.088393v1
53/8/1462    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rodríguez-Cabaleiro, D.
Right arrow Articles by Thienpont, L. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rodríguez-Cabaleiro, D.
Right arrow Articles by Thienpont, L. M.

Received on March 6, 2007
Accepted on May 31, 2007

Endocrinology and Metabolism

Pilot Study for the Standardization of Insulin Immunoassays with Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry

Diego Rodríguez-Cabaleiro 1, Katleen Van Uytfanghe 1, Veronique Stove 2, Tom Fiers 2, Linda M. Thienpont 1*

1 Laboratory for Analytical Chemistry, Faculty of Pharmaceutical Sciences, Ghent University, Ghent, Belgium
2 Laboratory for Hormonology and Department of Endocrinology, Ghent University Hospital, Ghent, Belgium

* To whom correspondence should be addressed. E-mail: linda.thienpont{at}ugent.be.

Background: An international working group convened by the American Diabetes Association (ADA) called for a reference measurement procedure for use in a trueness-based standardization project of insulin immunoassays. In view of this demand, we conducted a pilot study to investigate the feasibility of such a standardization project with our isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/tandem MS) procedure.

Methods: We evaluated the precision, accuracy, and limit of quantification (LoQ) of the ID-LC/tandem MS procedure by use of insulin-free serum supplemented with insulin to give 3 pools with concentrations of 0.0796, 0.769, and 5.56 µg/L. We conducted a pilot method comparison study with 4 immunoassays and 80 samples from fasting and glucose-stimulated patients.

Results: The within-run and total imprecision (CV) ranged from 3.2% to 6.3% and from 4.9% to 12.1% (listing sequence from the high to the low pool). The recovery from supplemented insulin-free sera ranged from 101.8% to 104.1%, and the LoQ was 0.07 µg/L (12 pmol/L). Weighted Deming regression and correlation analysis of the method-comparison data showed considerable between-assay variation for the immunoassays but, with the exception of one assay, excellent correlation with ID-LC/tandem MS. Recalibration of the immunoassay results considerably reduced the between-assay variation. Moreover, after recalibration, 3 of the 4 assays fulfilled the total error specification of 32% proposed by the ADA Workgroup.

Conclusions: Recalibration of insulin assays by regression equations established from method comparison with ID-LC/tandem MS can result in successful standardization and fulfillment of the total error criterion proposed by the ADA Workgroup.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. N. Hoofnagle, J. O. Becker, M. H. Wener, and J. W. Heinecke
Quantification of Thyroglobulin, a Low-Abundance Serum Protein, by Immunoaffinity Peptide Enrichment and Tandem Mass Spectrometry
Clin. Chem., November 1, 2008; 54(11): 1796 - 1804.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. E. Manley, S. D. Luzio, I. M. Stratton, T. M. Wallace, and P. M.S. Clark
Preanalytical, Analytical, and Computational Factors Affect Homeostasis Model Assessment Estimates
Diabetes Care, September 1, 2008; 31(9): 1877 - 1883.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2007 by the American Association for Clinical Chemistry.