Clinical Chemistry AACC Online Job Center spacer gif
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2007.091181v1, 2007; 10.1373/clinchem.2007.091181
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.091181v1
53/11/1990    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Todd, J.
Right arrow Articles by Goix, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Todd, J.
Right arrow Articles by Goix, P.

Received on May 3, 2007
Accepted on August 29, 2007

General Clinical Chemistry

Ultrasensitive Flow-based Immunoassays by Use of Single-Molecule Counting

John Todd 1*, Bob Freese 1, Ann Lu 1, Douglas Held 1, Jennifer Morey 1, Richard Livingston 1, Philippe Goix 1

1 Singulex, Inc., Hayward, CA

* To whom correspondence should be addressed. E-mail: j.todd{at}singulex.com.

Background: Immunoassay (IA) technology has expanded the clinical utility of protein biomarkers, but demands for increased sensitivity, dynamic reporting ranges, and small sample volumes has limited the potential clinical usefulness of many biomarkers. We assessed the performance, including limits of detection (LODs) and the dynamic reporting range of an IA-based technology, Erenna Immunoassay System, for a series of biomarkers, including cardiac troponin I (cTnI).

Methods: Erenna IAs were used with 10 different and clinically important biomarkers to ascertain the LOD with various sample sizes (10 µL to 200 µL).

Results: The Erenna Immunoassay System generated LODs of 10–100 pg/L using 100 µL of sample. For cTnI, the LOD was 0.2 ng/L and a 10% CV was seen between 0.78 and 1.6 ng/L.

Conclusions: The Erenna IA-based technology reproducibly measures protein biomarkers with detection limits of 10–100 pg/L, with a dynamic range of >4.5 logs in sample volumes of 50–150 µL.