Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2007.099812v1, 2008; 10.1373/clinchem.2007.099812
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.099812v1
54/6/956    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hartmann, M.
Right arrow Articles by Templin, M. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hartmann, M.
Right arrow Articles by Templin, M. F.

Received on November 1, 2007
Accepted on March 26, 2008

Automation and Analytical Techniques

Expanding Assay Dynamics: A Combined Competitive and Direct Assay System for the Quantification of Proteins in Multiplexed Immunoassays

Michael Hartmann 1, Monika Schrenk 1, Anette Döttinger 1, Sarah Nagel 1, Johan Roeraade 2, Thomas O. Joos 1, Markus F. Templin 1*

1 NMI–Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany
2 Department of Analytical Chemistry, Royal Institute of Technology, Stockholm, Sweden

* To whom correspondence should be addressed. E-mail: templin{at}nmi.de.

BACKGROUND: The concurrent detection and quantification of analytes that vary widely in concentration present a principal problem in multiplexed assay systems. Combining competitive and sandwich immunoassays permits coverage of a wide concentration range, and both highly abundant molecules and analytes present in low concentration can be quantified within the same assay.

METHODS: The use of different fluorescence readout channels allows the parallel use of a competitive system and a sandwich configuration. The 2 generated assay signals are combined and used to calculate the amount of analyte. The measurement range can be adjusted by varying the competitor concentration, and an extension of the assay system's dynamic range is possible.

RESULTS: We implemented the method in a planar protein microarray–based autoimmune assay to detect autoantibodies against 13 autoantigens and to measure the concentration of a highly abundant protein, total human IgG, in one assay. Our results for autoantibody detection and IgG quantification agreed with results obtained with commercially available assays. The use of 2 readout channels in the protein microarray–based system reduced spot-to-spot variation and intraassay variation.

CONCLUSIONS: By combining a direct immunoassay with a competitive system, analytes present in widely varying concentrations can be quantified within a single multiplex assay. Introducing a second readout channel for analyte quantification is an effective tool for spot-to-spot normalization and helps to lower intraassay variation.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. G. Kattah, P. J. Utz, and I. Balboni
Protein Microarrays Address the Elephant in the Room
Clin. Chem., June 1, 2008; 54(6): 937 - 939.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2008 by the American Association for Clinical Chemistry.