Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: clinchem.2008.103432v1, 2008; 10.1373/clinchem.2008.103432
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2008.103432v1
54/8/1356    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mak, C. M.
Right arrow Articles by Tam, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mak, C. M.
Right arrow Articles by Tam, S.

Received on January 15, 2008
Accepted on May 17, 2008

General Clinical Chemistry

Diagnostic Accuracy of Serum Ceruloplasmin in Wilson Disease: Determination of Sensitivity and Specificity by ROC Curve Analysis among ATP7B-Genotyped Subjects

Chloe M. Mak 1, Ching-Wan Lam 2*, Sidney Tam 3

1 Department of Chemical Pathology, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China, and Division of Clinical Biochemistry, Queen Mary Hospital, Hong Kong SAR, China
2 Department of Chemical Pathology, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong SAR, China
3 Division of Clinical Biochemistry, Queen Mary Hospital, Hong Kong SAR, China

* To whom correspondence should be addressed. E-mail: ching-wanlam{at}cuhk.edu.hk.

BACKGROUND: A serum ceruloplasmin concentration below 0.20 g/L is conventionally considered as one of the major diagnostic criteria for Wilson disease. This decision threshold has not been fully validated for its diagnostic characteristics, however. In this study, we evaluated various decision thresholds of serum ceruloplasmin concentration in the diagnosis of Wilson disease based on genotype-verified Wilson disease patients, carriers, and normal individuals.

METHODS: Serum ceruloplasmin concentration was measured by a nephelometric method in 57 Wilson disease patients and 71 family members (49 heterozygotes and 22 wild-type homozygotes), a validation group of 25 subjects clinically suspected of Wilson disease, and 690 normal individuals. We performed ROC analysis using Analyze-it software and confirmed the genotypes by direct DNA sequencing of ATP7B.

RESULTS: Serum ceruloplasmin concentrations <0.20, 0.14, and 0.10 g/L showed positive predictive values of 48.3%, 100%, and 100%, respectively, and negative predictive values of 98.7%, 97.1%, and 91.9%. In the validation group, a serum ceruloplasmin threshold of 0.14 g/L rendered 100% sensitivity and specificity. Forty of 690 healthy subjects had serum ceruloplasmin concentrations <0.20 g/L; however, these 40 individuals had normal genotypes by DNA sequencing, and none of the 40 had ceruloplasmin concentrations <0.14 g/L.

CONCLUSIONS: The diagnostic accuracy for Wilson disease using a serum ceruloplasmin concentration of 0.14 g/L as the local decision threshold was better than that using a threshold of 0.20 g/L. We suggest that laboratories providing ceruloplasmin assays determine decision thresholds based on local populations.